Wall Mount & Ceiling Type

Technical Specification

Dimensions 180 x 240 x 1500 mm ( W x D x H )
Electrical Power 280W
Noise 48 db - 55 db
Air Flow 285 - 340 m3 / h
Microorganisms Elimination Effect > % 99.9
Maintenance 16.000 hrs +
Installation Wall & Ceiling

Product Description

WHY UVCpectra Tube ?
 

  •   99.9% impact in a single pass by the usage of reliable solar beams on high-efficiency devices
  •   No need for additional technology nor engineering.
  •   It has no side effects on animal, the environment and human health.
  •   Usage time exceeding 9000 hours.
  •   Recoups investment costs within months with its product process savings and safety measures

 

Summary of Ultraviolet Studies on Coronavirusses

 

Microbe D90 dose ( J/m2) UV k (m2/J) Base Paies (kb) Source
Coronavirus 7 0,35120 30741 Walker 2007
Berne virus (Coronaviridae) 7 0,32100 28480 Weiss 1986
Murine Coronavirus (MHV) 15 0,15351 31335 Hirano 1978
Canine Coronavirus (CCV) 29 0,08079 29278 Saknimit 1988
Murine Coronavirus (MHV) 29 0,08079 31335 Saknimit 1988
SARS Coronavirus CoV-P9 40 0,05750 29829 Duan 2003
Murine Coronavirus (MHV) 103 0,02240 31335 Liu 2003
SARS Coronavirus (Hanoi) 134 0,01720 29751 Kariwa 2004
SARS Coronavirus (Urbani) 2410 0,00096 29751 Darnell 2004
 
Avarage 308 0,00747 including all studies
Avarage excluding outliers 58 0,03960 excluding Walker, Weiss & Darnell