| Dimensions | 600 x 400 x 1600 mm ( W x D x H ) |
| Electrical Power | 300 Watts |
| Noise | 48 db - 55 db |
| Air Flow | 285 - 340 m3 / h |
| Microorganisms Elimination Effect | > % 99.9 |
| Filter | Molecular filter |
| Maintenance | 16.000 hrs. + |
| Installation | No Assembly Required |
With the use of UVC bulbs directly in a closed area; the effect of destroying micro-organisms is not guaranteed due to the limited dose of superficial irradiation and many reducing factors. Destroys micro-organisms at the rate of LOG 0.8 UVCpectra air disinfection device eliminates micro-organisms with high technology at maximum dose and steadily without requiring any additional engineering. It destroys micro organisms at the rate of LOG 3.6.
| Microbe | D90 dose ( J/m2) | UV k (m2/J) | Base Paies (kb) | Source |
|---|---|---|---|---|
| Coronavirus | 7 | 0,35120 | 30741 | Walker 2007 |
| Berne virus (Coronaviridae) | 7 | 0,32100 | 28480 | Weiss 1986 |
| Murine Coronavirus (MHV) | 15 | 0,15351 | 31335 | Hirano 1978 |
| Canine Coronavirus (CCV) | 29 | 0,08079 | 29278 | Saknimit 1988 |
| Murine Coronavirus (MHV) | 29 | 0,08079 | 31335 | Saknimit 1988 |
| SARS Coronavirus CoV-P9 | 40 | 0,05750 | 29829 | Duan 2003 |
| Murine Coronavirus (MHV) | 103 | 0,02240 | 31335 | Liu 2003 |
| SARS Coronavirus (Hanoi) | 134 | 0,01720 | 29751 | Kariwa 2004 |
| SARS Coronavirus (Urbani) | 2410 | 0,00096 | 29751 | Darnell 2004 |
| Avarage | 308 | 0,00747 | including all studies | |
| Avarage excluding outliers | 58 | 0,03960 | excluding Walker, Weiss & Darnell | |